THEORETICAL ASPECTS OF COTTON LINT HUMIDIFICATION USING A FOUR-SECTION ULTRASONIC AEROSOL DEVICE BEFORE BALING
Tadjibaev Rasul Karimovich, Rakhmonov Zaylobiddin Obbosbek ugli
Fergana Politechnics Institute
- Konferensiya / to'plam
- Aniq va tabbiiy fanlarni rivojlantirishda Raqamli texnilogiyalarning o'rni: muammo va innovatsion yechimlar
- Nashr ma'lumotlari
- 2024, 4-5,oktabr
- Yil
- 2024
Annotatsiya
A four-section ultrasonic humidification device for cotton lint is proposed, combining a 1.7 MHz aerosol generator with alternating cross-flow. The GAB–LDF model predicts a reduction in moisture non-uniformity from 12.7% to 4.5% at 0.30 kg/(m²·s) air mass flux and 8 s residence time. For a capacity of 2.5 t/h, the design requires a 4.63 m² humidification area, approximately 4,300 m³/h airflow and 20 aerosol modules. The theoretical results provide a basis for experimental validation and industrial implementation.